-40%
Oscilloscope Current Probe 25MHz Max. Current 20A BNC Connector Accuracy 3%
$ 234.96
- Description
- Size Guide
Description
Note:1. Will ship via
express mail service or SpeedPAK
to USA, Canada, Australia, New Zealand, Ireland, Austria, Belgium, Denmark, Germany, France, Finland, Luxemburg, Malta, Norway, Sweden, Swiss, Spain, Italy, UK, Japan, Korea, Thailand, Malaysia, Indonesia, Philippine and Singapore customers.
2. Customers from other countries pls contact us in advance to confirm different shipping charges before you order.
ICP5025
ICP5000 series current probe is able to measure up to 50MHz current signals with <3%DC accuracy error through the advanced close loop technology with built-in transducer, which is mainly used for current measurement in various industrial application, and its current range up to 20A or 40A (DC + peak AC).
More advantage, this current probe is well matched with IIP1000 series high voltage differential probe on signal delay, the error of delay <1ns, this offers great benefit for end customer to measure real time voltage and current signal in the same time, and perform power analysis more conveniently, but much less expensive.
This probe is provided with high precision and reliability performance, as well very portable, durable structure.
Application field:
■Non touch current measurement ■Power analysis/measurement
■New energy application design ■LED power driving design
■Switch Mode PS design
■Power conversion design
■Reverse PS
,
UPS PS ■Welding, plating PS measurement
■Variable Frequency Drive(VFD) ■Motor monitor and maintenance
■Electrical/Electronic experiment ■Low Voltage Apparatus experiment
■Power electronics and electric drives
Major Specification
Technical specification
Model
ICP5025
ICP5050
Bandwidth
(
-3dB
)
25MHz
50MHz
Rise time
14ns
7ns
Accuracy
± 3%
Current conversion ratio
0.1V/A, 1MΩ
Max. current measurement
20A
(
DC + peak AC
)
Peak pulse current measurement
50A
(
Tp≤10μs
)
Max. tested voltage to Ground
400V
(
DC + peak AC
)
Noise
≤1mVrms
Linearity
±1%
Time delay
20ns±1ns
AC adapter output
DC9V
,
1000mA
AC adapter input
AC100-240V
,
50-60Hz
Mechanical Specification
Max. conductor diameter
4.5mm
Cable length
About
150cm
Probe body dimension
188x40x24
(
mm
)
Probe body weight
150g
Environment characteristics
Operating temperature
0-40
C
Storage temperature
-10-45
C
Operating RH
85%RH
Storage RH
90%RH
Operating altitude
3000m
Storage altitude
12000m
Accessories: PDF manual, power adapter(US, Euro, AU and UK plug is available), case.